Flame Photometer
A Flame Photometer is used to measure the concentration of metal ions in test materials, like K, Na, Li, Ca and Ba. It can be widely used in agriculture, mineral extraction, food, Chemical composites, pathology research, clinical and pharmaceutical sample analysis, etc. Our flame photometers are perfect for accurate and reliable metal ion analysis because of their professional and user-friendly design.
Main Features
1. 7 inch easy-to-use capacitive touch screen.
2. Direct reading concentration of Na, K, Li, Ca, Ba.
3. Flameout protection system ensures your safety.
4. Automatic calculation of test sample correlation.
5. Flame optimization provides good quality control.
6. USB port for data transfer in addition to touchscreen display.
7. Single point calibration at maximum concentration.
8. LPG burning gas and standard air filter in the device.
9. Standard air compressor maintains steady flame conditions.
10. Options to choose various concentration units
Specifications
Model |
FP7500 |
FP7400 |
FP7303 |
FP7302 |
FP7301 |
FP7202 |
FP7201 |
|
Display |
7-inch capacitive touchscreen |
|||||||
Readings |
Concentration value/Energy |
|||||||
Range |
0.000-999.9/0-65535 |
|||||||
Elements Analyzed |
K, Na, Li, Ca, Ba |
K, Na, Li, Ca |
K, Na, Ba |
K, Na, Ca |
K, Na, Li |
K, Na |
K, Na |
|
Channels |
5 |
4 |
3 |
3 |
3 |
2 |
2 |
|
Measureing Range(ppm) |
K |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
0-100 |
Na |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
0-160 |
|
Li |
0-100 |
0-100 |
—— |
—— |
0-100 |
—— |
—— |
|
Ca |
0-1000 |
0-1000 |
—— |
0-1000 |
—— |
—— |
—— |
|
Ba |
0-3000 |
—— |
0-3000 |
—— |
—— |
—— |
—— |
|
Detection Limit (mmol/L) |
K |
≤0.004 |
≤0.004 |
≤0.004 |
≤0.004 |
≤0.004 |
≤0.004 |
≤0.004 |
Na |
≤0.008 |
≤0.008 |
≤0.008 |
≤0.008 |
≤0.008 |
≤0.008 |
≤0.008 |
|
Li |
≤0.015 |
≤0.015 |
—— |
—— |
≤0.015 |
—— |
—— |
|
Ca |
≤0.050 |
≤0.050 |
—— |
≤0.050 |
—— |
—— |
—— |
|
Ba |
≤0.044 |
—— |
≤0.044 |
—— |
—— |
—— |
—— |
|
Linearity Error (mmol/L) |
K |
≤0.005 |
≤0.005 |
≤0.005 |
≤0.005 |
≤0.005 |
≤0.005 |
≤0.005 |
Na |
≤0.03 |
≤0.03 |
≤0.03 |
≤0.03 |
≤0.03 |
≤0.03 |
≤0.03 |
|
Li |
≤0.021 |
≤0.021 |
—— |
—— |
≤0.021 |
—— |
—— |
|
Ca |
≤0.075 |
≤0.075 |
—— |
≤0.075 |
—— |
—— |
—— |
|
Ba |
≤0.066 |
—— |
≤0.066 |
—— |
—— |
—— |
—— |
|
Response Time |
<8S |
|||||||
Aspiration Rate |
<6ml/min |
|||||||
Stability |
≤3% drift within 15s |
|||||||
Reproducibility |
≤3% |
|||||||
Calibration Curve |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Printer |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
|
Fuel Supply |
LPG |
|||||||
Output |
USB port |
|||||||
Power Supply |
AC 220V/50Hz or AC 110V/60Hz |
|||||||
Packing Size |
71*38*52cm/20kg |
- Previous:S-100 Intelligent stirrer