Flame & Graphite

AA60 Series Flame & Graphite AAS

Word:[Big][Middle][Small] QR Code 2023-8-24     Viewed:    

The AAS is fully PC controlled with modern and compact design. They have flexible configuration and different accessories to meet variable requirements. Advance optical system can guarantee stable and reliable performance. Unique and intelligent gas control module can ensure the device safety. The AAS can test more than 70 elements including metallic and non-metallic elements, which can be used widely in petrochemistry, metallurgy, mining, geology, material analysis, food and pharmacy.

 

Main Features

1. Total reflection optical system can reduce energy loss to ensure better signal-to-noise ratio and lower detection limit.

2. Standard deuterium lamp background correction for all models. Standard high-performance self-absorption background correction for double beam models, and optional for the models with 8-lamp turret.

3. Automatic pneumatic control module ensures the device safety and accuracy and protects the operator and device better.

4. Automatic vertical 4/8-lamp turret supports high-performance element lamp, can be rotated 360 degrees and make sure the test accuracy and reliability is not affected by the gravity.

5. Automatic burner adjustment ensures the maximum sensitivity, you can raise or lower the burner according to the reading. Flame detection enhances the device safety.

6. Modular design for optical system and circuit makes the maintenance and repair simple.

7. Professional, automatic and easy to operate full operation RGWIN AAS software under MS window system and QA/QC function.

8. Transversely heated graphite tube ensures the consistency of the gas temperature in the graphite tube, and make the sample reach the atomic temperature instantly and simultaneously, improve atomic efficiency and test accuracy, ensure that the analysis results are more accurate, reduce the requirements for furnace body and prolong lifetime.

9. Safety protection system: flame monitoring (acetylene will be turned off automatically if there is any abnormality and show warning information), unique acetylene protector (warning information will be shown if the leak acetylene concentration is beyond the alert concentration), pressure monitoring (the flame will not work if the air or acetylene pressure is not normal, the graphite furnace will not work if the argon pressure is too high or too low), graphite tube installation self-inspection.


Flame & Graphite Furnace AAS Specification

Model

AA6018

AA6028

Optical System

Optical Type

Single beam

Double beam

Monochromator

Czerny-Turner type with focal lengths at 350mm

Wavelength Range

190-900nm

Grating

Holographic diffraction grating with 1800 lines/mm

Slits

Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm

Wavelength Accuracy

±0.2 nm

±0.15 nm

Wavelength Repeatability

±0.1nm

±0.05nm

Lamp Holder

Automated 8-lamp turret

Detector

Wide range UV sensitive photomultiplier tube

Photometric

Performance

Reading Mode

Transmittance(T), Absorbance(A), Concentration(C)

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift (Cu)

0.003A/30 min

0.002A/30 min

Dynamic Baseline Drift (Cu)

0.005A/15 min

0.004A/15 min

Background Correction

Deuterium (D2) Background Correction and

Self-absorption Background Correction

Flame Analysis

Characteristic Concentration

Cu0.035ug/ml

Cu0.02ug/ml

Detection Limit

Cu0.006ug/ml

Cu0.004ug/ml

Repeatability (Cu)

RSD0.6%

RSD0.5%

Acetylene Flow Control

Auto 12-level

Auto 12-level

Air Flow Control

Auto 4-level

Auto 4-level

Nebulizer

High efficiency glass

Burner Adjustment

Automatic up and down

Burner Head

Titanium alloy 100mm burner for air/acetylene operation

Premix Chamber

Corrosion resistant

Safety Protection

Flame sensor, gas leak sensor, gas pressure sensor

Graphite

Furnace

Analysis

Characteristic Concentration

Cd0.6pg , Cu20pg

Cd0.5pg , Cu20pg

Detection Limit

Cd1.0pg , Cu25pg

Cd0.8pg , Cu25pg

Repeatability (Cu)

RSD3%

RSD2.5%

Temperature Range

Ambient -3000

Ambient -3000

Ramp and holding time

1-255s

1-255s

Heating Rate

Maximum linear heating rate 2000/s

Atomization Heating Method

Light-controlled heating, Time-controlled heating, General heating

Gas Flow Rate Inside Tube

1 L/min

1 L/min

Gas Flow Rate Outside Tube

4-speed adjustable (0, 50, 200, 250ml/min)

Safety Protection

Water flow sensor, Argon pressure sensor, Furnace body temperature sensor, Graphite tube installation self-inspection.

Data Processing

Software

RGWIN AAS software package

Analytical Method

Flame AA, Flame AE, Hydride Generation

Concentration Calculation

Method

Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation

Repeated Measurement Times

1-30 times, calculate the average, show SD and RSD value of absorbance and concentration

QA/QC Function

Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration

Report Printing

Parameter printing, resulting printing

Communication Port

Standard RS-232

Others

Computer

External(excluded)

Dimension & Weight

850*650*550MM(W*D*H), 100Kg

Power Supply

110/220V, 50/60Hz

Working Environment

Temperature 10 ~ 35 °C, Humidity85%

Packing List

NO.

Description

Qty

NO.

Description

Qty

1

Main Unit

1

12

Acetylene pressure reducing valve connector

1

2

Power Cable

1

13

5A fuse

3

3

Data Cable

1

14

Argon pressure reducing valve connector

1

4

Screw Driver

1

15

Graphite tube

5

5

Cu HCL

1

16

High power socket

1

6

Cd HCL

1

17

6*4mm argon tube(transparent)

10m

7

Air Compressor

1

18

5-50ul pipette

1

8

6mm acetylene tube(orange)

10m

19

200ul pipette tip(1000pc/bag)

1

9

6mm air tube(transparent)

10m

20

6*10mm cooling water tube

6m

10

USB(manual and software)

1

21

Graphite furnace camera connection cable

1

11

Drain Tube

2m

22

Ignition filament

5

Go Back
Print
More